Part Number Hot Search : 
154807 ST72321 TSHG6210 C1165 LT1676 D401A DIP05 B3701
Product Description
Full Text Search
 

To Download MUR820PBF Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Bulletin PD-20898 12/04
MUR820PBF
Ultrafast Rectifier
Features
* * * * * Ultrafast Recovery Time Low Forward Voltage Drop Low Leakage Current 175C Operating Junction Temperature Lead-Free ("PbF" suffix)
trr = 25ns IF(AV) = 8Amp VR = 200V
Description/ Applications International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with optimized performance of forward voltage drop and ultra fast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as free-wheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers.
Absolute Maximum Ratings Parameters
VRRM IF(AV) IFSM IFM TJ, TSTG Peak Repetitive Peak Reverse Voltage Average Rectified Forward Current Total Device, (Rated V R ), TC = 150C Non Repetitive Peak Surge Current Peak Repetitive Forward Current (Rated V R , Square wave, 20 KHz), TC = 150C Operating Junction and Storage Temperatures -65 to 175 C 100 16
Max
200 8
Units
V A
Case Styles
MUR820PBF
Base Cathode
1
3
Cathode
Anode
TO-220AC
www.irf.com
1
MUR820PBF
Bulletin PD-20898 12/04
Electrical Characteristics @ TJ = 25C (unless otherwise specified)
Parameters
VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage IR Reverse Leakage Current CT LS Junction Capacitance Series Inductance 25 8.0 0.975 0.895 5 250 V V A A pF nH IF = 8A IF = 8A, TJ = 150C VR = VR Rated TJ = 150C, VR = VR Rated VR = 200V Measured lead to lead 5mm from package body .
Min Typ Max Units Test Conditions
200 V IR = 100A
Dynamic Recovery Characteristics @ TJ = 25C (unless otherwise specified)
Parameters
trr Reverse Recovery Time
Min Typ Max Units Test Conditions
-
20 34
35 25 -
ns
IF = 1.0A, diF/dt = 50A/s, VR = 30V IF = 0.5A, IR = 1.0A, IREC = 0.25A TJ = 25C TJ = 125C IF = 8A VR = 160V diF /dt = 200A/s
IRRM
Peak Recovery Current
-
1.7 4.2 23 -
75
A
TJ = 25C TJ = 125C
Qrr
Reverse Recovery Charge
-
nC -
TJ = 25C TJ = 125C
Thermal - Mechanical Characteristics
Parameters
TJ TStg RthJC RthJA RthCS Wt Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Thermal Resistance, Junction to Ambient Thermal Resistance, Case to Heatsink Weight
Min
- 65 - 65 -
Typ
0.5 2.0 0.07 -
Max
175 175 3.0 50 12 10 MUR820
Units
C
C/ W
g (oz) Kg-cm lbf.in
Mounting Torque
6.0 5.0
Marking Device
Mounting Surface, Flat, Smooth and Greased
2
www.irf.com
MUR820PBF
Bulletin PD-20898 12/04
100
(A)
100
T J = 175C 150C
10
Reverse Current - I
R
1
125C 100C
0.1
25C
Instantaneous Forward Current - I F (A)
10
T = 175C
J
0.01
0.001 0 50 100 150 200 250
Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage
TJ = 150C TJ = 25C
1000
1
Junction Capacitance - C T (pF)
T = 25C J
100
0.1 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 Forward Voltage Drop - VFM (V)
10
Thermal Impedance Z thJC (C/W)
10 1 10 100 1000
Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage
Fig. 1 - Typical Forward Voltage Drop Characteristics
1
D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01
Notes:
PDM
t1 t2 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc
0.1
Single Pulse (Thermal Resistance)
0.01 0.00001
0.0001
0.001
0.01
0.1
1
t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
www.irf.com
3
MUR820PBF
Bulletin PD-20898 12/04
180
Allowable Case Temperature (C) Average Power Loss ( Watts )
10
170
DC
8
D = 0.01 D = 0.02 D = 0.05 D = 0.10 D = 0.20 D = 0.50
160
6
150 Square wave (D = 0.50)
Rated Vr applied
4 RMS Limit
DC
140
see note (2)
2
130 0 3 6 9 12 Average Forward Current - IF(AV) (A)
0 0 3 6 9 12
Average Forward Current - IF(AV) (A) Fig. 6 - Forward Power Loss Characteristics
Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current
50
200
40
IF = 16A IF = 8 A IF = 4 A
VR = 160V TJ = 125C TJ = 25C
160
IF = 16A IF = 8 A IF = 4 A
trr ( nC )
30
Qrr ( nC )
VR = 160V TJ = 125C TJ = 25C
120
80
20 40
10 100
1000
0 100
1000
di F /dt (A/s ) Fig. 7 - Typical Reverse Recovery vs. di F /dt
di F /dt (A/s ) Fig. 8 - Typical Stored Charge vs. di F /dt
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = V R1 x IR (1 - D); IR @ VR1 = rated VR
4
www.irf.com
MUR820PBF
Bulletin PD-20898 12/04
Reverse Recovery Circuit
VR = 200V
0.01 L = 70H D.U.T.
di F /dt dif/dt ADJUST G
D IRFP250 S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
IF 0
t rr ta tb
4
2
Q rr I RRM
0.5 I RRM di(rec)M/dt 0.75 I RRM
5
1
/dt di fF/dt
1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going I F to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current
4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
MUR820PBF
Bulletin PD-20898 12/04
Outline Table
10.54 (0.41) MAX. 3.78 (0.15) 3.54 (0.14) 15.24 (0.60) 14.84 (0.58) 1 14.09 (0.55) 13.47 (0.53) 3 3.96 (0.16) 3.55 (0.14) 2.04 (0.080) MAX. 1.40 (0.05) 1.15 (0.04) 0.94 (0.04) 0.69 (0.03) 2.89 (0.11) 2.64 (0.10) 0.10 (0.004) 2.92 (0.11) 2.54 (0.10) TERM 2 DIA. 6.48 (0.25) 6.23 (0.24) 2 1.32 (0.05) 1.22 (0.05)
Base Cathode
1
3
Cathode
Anode
1 4.57 (0.18) 4.32 (0.17)
3
0.61 (0.02) MAX.
5.08 (0.20) REF.
Conforms to JEDEC Outline TO-220AC Dimensions in millimeters and (inches)
Part Marking Information
IRXC Assembly Line EXAMPLE: THIS IS A MUR820 LOT CODE 1789 ASSEMBLED ON WW 19, 2001 IN THE ASSEMBLY LINE "C" INTERNATIONAL RECTIFIER LOGO DATE CODE ASSEMBLY LOT CODE P = LEAD-FREE YEAR 1 = 2001 WEEK 19 LINE C PART NUMBER
IRMX Assembly Line EXAMPLE: THIS IS A MUR820 LOT CODE 1789 ASSEMBLED ON WW 19, 2001 IN THE ASSEMBLY LINE "C" INTERNATIONAL RECTIFIER LOGO
PART NUMBER
DATE CODE ASSEMBLY LOT CODE YEAR 1 = 2001 WEEK 19 P = LEAD-FREE
6
www.irf.com
MUR820PBF
Bulletin PD-20898 12/04
Ordering Information Table
Device Code
MUR
1
8
2
20
3
PbF
4
1 2 3 4
-
Ultrafast MUR Series Current Rating (8 = 8A) Voltage Rating (20 = 200V) none = Standard Production PbF = Lead-Free Tube Standard Pack Quantity : 50 pieces
Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 12/04
www.irf.com
7


▲Up To Search▲   

 
Price & Availability of MUR820PBF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X